High Power Terminations / Loads

Micro Communications manufactures different types of loads for the medical, scientific, commercial, and military markets from 0.32 to 10.0 GHz – from special application units for coaxial to ultra-high power waveguide systems. Our innovative designs include an extremely narrowband compact water load, for a single frequency, which is completely sufficient for particle accelerators.

MCI engineers welcome the opportunity to discuss your project-specific requirements for power terminations and loads:

  • Low VSWR.
  • Ability to design and build "dry loads" with a wide variety of cooling methods such as air convection, forced-air or liquid-cooling.
  • "Directly heated liquid loads" can be designed to use water, de-ionized water or water-glycol mixtures.

Loads described below are only representative of our product line. Please contact us for your specific needs.

 

High Power Convection Cooled Terminations

WG Size EIA WR

Part Number*

Frequency (GHz)

VSWR (Max.)

Peak Power (KW)

Average Power (W)

Maximum Length (Inches)

WR112

341435C-XXX

7.05-10.00

 1.10

500

2500

14.0

WR137

341535C-XXX

5.85-8.20

 1.10

700

2700

20.0

WR159

341735C-XXX

4.90-7.05

 1.10

1000

3000

22.0

WR187

341935C-XXX

3.95-5.85

 1.10

1800

3200

24.0

WR229

342235C-XXX

3.30-4.90

 1.10

2600

3500

26.0

WR284

341235C-XXX

2.60-3.95

 1.10

3500

4500

28.0

WR430

343935C-XXX

2.6-3.95

 1.10

5000

6000

31.0

WR650

343635C-XXX

1.12-1.70

 1.10

8500

8000

34.0

* Part number –XXX designation depends on flange type.

 

HighHigh Power Water Cooled Terminations

WG Size EIA WR

Part
Number*

Frequency (GHz)

VSWR (Max.)

Peak Power (KW)

Average Power (W)

Maximum Length (Inches)

WR112

341445C-XXX

7.05-10.00

 1.10

500

4000

14.0

WR137

341545C-XXX

5.85-8.20

 1.10

700

5000

20.0

WR159

341745C-XXX

4.90-7.05

 1.10

1000

6200

22.0

WR187

341945C-XXX

3.95-5.85

 1.10

1800

8000

24.0

WR229

342245C-XXX

3.30-4.90

 1.10

2600

8500

26.0

WR284

341245C-XXX

2.60-3.95

 1.10

3500

10000

28.0

WR430

343945C-XXX

2.6-3.95

 1.10

5000

15000

31.0

WR650

343645C-XXX

1.12-1.70

 1.10

8500

25000

34.0

* Part number –XXX designation depends on flange type.

 

Transition Water Loads

 

Compact Water Load

High Power Water Loads

WG
Size

EIA WR

 Part
Number*

Frequency
Range**
(MHz)

VSWR
Max***

Inlet
Water
Temp.

Output
Water
Temp.
 (Max)

Peak Power (MW)

Average Power (KW)

Max. 
Coolant
Pressure

Load

TYPE

WR650

333150C-XXX

1120-1700

1.15

20°C
to
50°C

 85°C

5.5

150

45 PSIG

Water

Column

WR975

333030C-XXX

750-1120

1.15

20°C
to
70°C

 85°C

5

70

45 PSIG

Water

Column

WR1150

333300C-XXX

640-960

1.15

20°C
to
30°C

 85°C

5

300

100 PSIG

Water

Column

WR1800

348300C-XXX

410-620

1.15

20°C
to
50°C

95°C

5

300

100 PSIG

Water

Compact

WR2100

349300C-XXX

350-530

1.15

20°C
to
50°C

95°C

10

300

100 PSIG

Water

Compact

WR2300

342300C-XXX

320-490

1.15

20°C
to
50°C

95°C

10

500

100 PSIG

 Water

Compact

* P/N designation –xxx is assigned at time of order for specific frequency and required flange type. 
** Frequency is specified at time of order. Bandwidth of operation varies depending on design type.
     Please consult factory with your specific requirement.
*** Better VSWR can be obtained on some designs depending on load type and required bandwidth.

© 2016 Micro Communications